QUBINO SMART METER USER MANUAL Pdf Download (2024)

Qubino

The INNOVATIVE and SMALLEST

Smart meter

ORDERING CODE

Z-WAVE FREQUENCY

ZMNHTD1

868,4 MHz

ZMNHTD2

921,4 MHz

ZMNHTD3

908,4 MHz

ZMNHTD4

869,0 MHz

ZMNHTD5

916,0 MHz

This

Z-Wave module is

used for energy

measurements in single-phase electrical power

network and can be used in residential, industrial

and utility applications. Meters measure energy

directly in 2-wire networks according to the

principle of fast sampling of voltage and current

signals. A built-in microprocessor calculates

energy, power and power factor from the

measured signals.

The module can be controlled through Z-wave

network and it acts as repeater in order to

improve range and stability of Z-wave network.

It is designed to be mounted on DIN rail.

Installation

Before the installation disconnect power

supply.

Connect the module according to electrical

diagram.

Locate the antenna far from metal elements

(as far as possible).

Do not shorten the antenna.

Danger of electrocution!

Module installation requires a great degree

of skill and may be performed only by a

qualified and licensed electrician.

Even when the module is turned off, voltage

may be present on its terminals. Any works

on

configuration

changes

related

to

connection mode or load must be always

performed by disconnected power supply

(disable the fuse).

Note!

Do not connect the module to loads exceeding

recommended values. Connect the module only

in accordance to the below diagrams. Improper

connections

may

be

dangerous.

It

is

recommended to use 65 A fuses for the line

protection.

Package contents

Smart meter

Electrical diagram 230VAC

IR

IR

Notes for the diagram:

LI

Live input

NI

Neutral input

Lo

Live output

No

Neutral output

1

Input for IR external relay/Ext. relay

2

Neutral lead for input

4

Live lead for External relay output

5

Output for External relay (max. 3W)

S

Service button (used to add or

remove module from the Z-Wave

network).

LED1

Green - Power on (solid) / no ID

(blinking slow 1s) / Inc./Exc. mode

(blinking fast 0,5s)

Yellow on – output on (any) /

LED2

Yellow off – outputs off (both)

IR

Output for IR external relay

1imp/

Red - Pulse rate

Wh

Measurements

Voltage

V

Current

I

Power – Active

W

Power – Active total

kWh

Power – Reactive

var

Power – Reactive total

kvarh

Power – Apparent total

kVAh

Power Factor

PF

External relays

It is possible to connect two external relay to

Smart meter module. One controlled by built-in

optical (IR) communication port on the side,

second controlled by output on terminal 5.

Module Inclusion (Adding to Z-wave

network)

Connect module to power supply

enable add/remove mode on main controller

auto-inclusion (works for about 5 seconds

after connected to power supply) or

press service button S for more than 2

second

NOTE: For auto-inclusion procedure, first set

main controller into inclusion mode and then

connect module to power supply.

Module

Exclusion/Reset

(Removing

from Z-Wave network)

Connect module to power supply

bring module within maximum 1 meter (3 feet)

of the main controller,

enable add/remove mode on main controller

press service button S for more than 6

seconds.

By this function all parameters of the module are

set to default values and own ID is deleted.

If service button S is pressed more than 2 and

less than 6 seconds module is excluded, but

configuration parameters are not set to default

values.

Association

Association enables Smart meter module to

transfer commands

inside

Z-Wave network

directly to other Z-Wave modules.

Associated Groups:

Group

1:

Lifeline

group

(reserved

for

communication with the main controller), 1 node

allowed.

Configuration parameters

Parameter no. 7 – Input 1 switch function

selection

Available configuration parameters (data type is 1

Byte DEC):

default value 4

0 disabled

2 IR external relay control – mono stable

push button

3 IR external relay control - bi stable switch

4 External relay control – mono stable push

button

5 External relay control – bi stable switch

Parameter no. 10 - Activate / deactivate

functions ALL ON / ALL OFF

Available configuration parameters (data type is 2

Byte DEC):

default value 255

255 - ALL ON active, ALL OFF active.

0 - ALL ON is not active, ALL OFF is not

active

1 - ALL ON is not active, ALL OFF active

2 - ALL ON active, ALL OFF is not active

Smart meter module responds to commands ALL

ON/ ALL OFF that may be sent by the main

controller or by other controller belonging to the

system

Parameter no. 11 - Automatic turning off IR

external relay output after set time

When

IR

external

relay

is

ON

it

goes

automatically OFF after time defined by this

parameter. Timer is reset to zero each time the

module receive ON command regardless from

where it comes (push button, associated module,

controller,..). Available configuration parameters

(data type is 2 Byte DEC):

default value 0

0 = Auto OFF disabled

1 – 32535 = 1second – 32535 seconds. Auto

OFF enabled with define time, step is 1s.

Parameter no. 12 - Automatic turning on IR

external relay output after set time

When IR

external

relay

is

OFF

it

goes

automatically ON after time defined by this

parameter. Timer is reset to zero each time the

module receive OFF command regardless from

where it comes (push button, associated module,

controller,..). Available configuration parameters

(data type is 2 Byte DEC):

default value 0

0 = Auto ON disabled

1 – 32535 = 1second – 32535 seconds. Auto

ON enabled with define time, step is 1s.

Parameter no. 13 - Automatic turning off

External relay output after set time

When External relay is ON it goes automatically

OFF after time defined by this parameter. Timer

is reset to zero each time the module receive ON

command regardless from where it comes (push

button,

associated

module,

controller,..).

Available configuration parameters (data type is 2

Byte DEC):

default value 0

0 = Auto OFF disabled

1 – 32535 = 1second – 32535 seconds. Auto

OFF enabled with define time, step is 1s.

Parameter no. 14 - Automatic turning on

External relay after output set time

When External relay is OFF it goes automatically

ON after time defined by this parameter. Timer is

reset to zero each time the module receive OFF

command regardless from where it comes (push

button,

associated

module,

controller,..).

Available configuration parameters (data type is 2

Byte DEC):

default value 0

0 = Auto ON disabled

1 – 32535 = 1second – 32535 seconds. Auto

ON enabled with define time, step is 1s.

Parameter no. 40 – Power reporting in Watts

on power change

Set value means percentage, set value from 0 –

100 = 0% - 100%. Available configuration

parameters (data type is 1 Byte DEC):

default value 10

0 = Reporting disabled

1 – 100 = 1% - 100% Reporting enabled.

Power report is send (push) only when actual

power in Watts in real time changes for more

than set percentage comparing to previous

actual power in Watts, step is 1%.

NOTE: if power changed is less than 1W, the

report is not send (pushed), independent of

percentage set. When reporting Watts, module

will automatically reports also V (Voltage), A

QUBINO SMART METER USER MANUAL Pdf Download (2024)

References

Top Articles
Latest Posts
Article information

Author: Melvina Ondricka

Last Updated:

Views: 6110

Rating: 4.8 / 5 (48 voted)

Reviews: 95% of readers found this page helpful

Author information

Name: Melvina Ondricka

Birthday: 2000-12-23

Address: Suite 382 139 Shaniqua Locks, Paulaborough, UT 90498

Phone: +636383657021

Job: Dynamic Government Specialist

Hobby: Kite flying, Watching movies, Knitting, Model building, Reading, Wood carving, Paintball

Introduction: My name is Melvina Ondricka, I am a helpful, fancy, friendly, innocent, outstanding, courageous, thoughtful person who loves writing and wants to share my knowledge and understanding with you.