QUBINO SMART METER MANUAL Pdf Download (2024)

Qubino

The INNOVATIVE and SMALLEST

Smart Meter

ORDERING CODE

Z-WAVE FREQUENCY

ZMNHTD1

868,4 MHz

ZMNHTD2

921,4 MHz

ZMNHTD3

908,4 MHz

ZMNHTD4

869,0 MHz

ZMNHTD5

916,0 MHz

ZMNHTD8

865,2 MHz

This Z-Wave module is used for energy measurements in

single-phase electrical power network and can be used in

residential, industrial and utility applications. Meters

measure energy directly in 2-wire networks according to

the principle of fast sampling of voltage and current

signals. A built-in microprocessor calculates energy,

power and power factor from the measured signals.

The module can be controlled through Z-wave network

and it acts as repeater in order to improve range and

stability of Z-wave network.

It is designed to be mounted on DIN rail.

Installation

To prevent electrical shock and/or equipment

damage, disconnect electrical power: remove main

fuse or put on OFF position a main disconnection

switch (or circuit breaker if it is compliant to standard

IEC947-2), before installation or any servicing.

Make sure, that no voltage is present in the

installation.

Prevent the disconnecting device from being

switched on accidentally.

Connect the module according to electrical diagram.

Locate the antenna far from metal elements (as far

as possible).

Do not shorten the antenna.

Danger of electrocution!

Module installation requires a great degree of skill

and may be performed only by a qualified and

licensed electrician.

Even when the module is turned off, voltage may be

present on its terminals.

Note!

Do not connect the module to loads exceeding

recommended values. Connect the module only in

accordance to the below diagrams. Improper connections

may be dangerous.

Electrical installation must be protected by over current

protection fuse

with rated current up to

63A,

it must be

used according to wiring diagram to achieve appropriate

overload protection of the module.

Package contents

Smart Meter

Electrical diagram 230VAC

IR

Notes for the diagram:

LI

Live input

NI

Neutral input

Lo

Live output

No

Neutral output

1

Input for IR external relay/Ext. relay

2

Neutral lead for input

4

Live lead for External relay output

5

Output for External relay (max. 3W)

S

Service button (used to add or remove

module from the Z-Wave network).

LED1

Green - Power on (solid) / no ID (blinking

slow 1s) / Inc./Exc. mode (blinking fast

0,5s)

Yellow on – output on (any) / Yellow off –

LED2

outputs off (both)

IR

Output for IR external relay

Red - Pulse rate (On – no load indication)

1imp/Wh

Measurements

Voltage

V

Current

I

Power – Active

W

Power – Active total Import

kWh

Power – Active total Export

kWh

Power – Reactive

var

Power – Reactive total

kvarh

Power – Apparent total

kVAh

Power Factor

PF

External relays

It is possible to connect two external relay to Smart Meter

module. One controlled by built-in optical (IR)

communication port on the side, second controlled by

output on terminal 5.

Module Inclusion (Adding to Z-wave

network)

Connect module to power supply

enable add/remove mode on main controller

auto-inclusion (works for about 5 seconds after

connected to power supply) or

press service button S for more than 2 second

NOTE: For auto-inclusion procedure, first set main

controller into inclusion mode and then connect module to

power supply.

Module

Exclusion/Reset

(Removing

from Z-Wave network)

Connect module to power supply

bring module within maximum 1 Meter (3 feet) of the

main controller,

enable add/remove mode on main controller

press service button S for more than 6 seconds.

By this function all parameters

of the module are set to

default values and own ID is deleted.

If service button S is pressed more than 2 and less than 6

seconds module is excluded, but configuration

parameters are not set to default values.

Association

Association enables Smart Meter module to transfer

commands inside Z-Wave network directly to other Z-

Wave modules.

Associated Groups:

Group 1: Lifeline group (reserved for communication with

the main controller), 1 node allowed.

Configuration parameters

Parameter no. 7 – Input 1 switch function selection

Available congig. parameters (data type is 1 Byte DEC):

default value 4

0 - disabled

2 - IR external relay control – mono stable push

button

3 - IR external relay control - bi stable switch

4 - External relay control – mono stable push button

5 - External relay control – bi stable switch

Parameter no. 10 - Activate / deactivate functions ALL

ON / ALL OFF

Available config. parameters (data type is 2 Byte DEC):

default value 255

255 - ALL ON active, ALL OFF active.

0 - ALL ON is not active, ALL OFF is not active

1 - ALL ON is not active, ALL OFF active

2 - ALL ON active, ALL OFF is not active

Smart Meter module responds to commands ALL ON/

ALL OFF that may be sent by the main controller or by

other controller belonging to the system

Parameter no. 11 - Automatic turning off IR external

relay output after set time

When IR external relay is ON it goes automatically OFF

after time defined by this Parameter. Timer is reset to

zero each time the module receive ON command

regardless from where it comes (push button, associated

module, controller,..). Available configuration parameters

(data type is 2 Byte DEC):

default value 0

0 - Auto OFF disabled

1 - 32535 = 1second - 32535 seconds. Auto OFF

enabled with define time, step is 1s.

Parameter no. 12 - Automatic turning on IR external

relay output after set time

When IR external relay is OFF it goes automatically ON

after time defined by this Parameter. Timer is reset to

zero each time the module receive OFF command

regardless from where it comes (push button, associated

module, controller,..). Available configuration parameters

(data type is 2 Byte DEC):

default value 0

0 - Auto ON disabled

1 - 32535 = 1second - 32535 seconds. Auto ON

enabled with define time, step is 1s.

Parameter no. 13 - Automatic turning off External

relay output after set time

When External relay is ON it goes automatically OFF after

time defined by this parameter. Timer is reset to zero

each time the module receive ON command regardless

from where it comes (push button, associated module,

controller,..). Available configuration parameters (data

type is 2 Byte DEC):

default value 0

0 - Auto OFF disabled

1 - 32535 = 1second - 32535 seconds. Auto OFF

enabled with define time, step is 1s.

Parameter no. 14 - Automatic turning on External

relay after output set time

When External relay is OFF it goes automatically ON after

time defined by this parameter. Timer is reset to zero

each time the module receive OFF command regardless

from where it comes (push button, associated module,

controller,..).

Available configuration parameters (data

type is 2 Byte DEC):

default value 0

0 - Auto ON disabled

1 - 32535 = 1second - 32535 seconds. Auto ON

enabled with define time, step is 1s.

Parameter no. 40 – Power reporting in Watts on power

change

Set value means percentage, set value from 0 – 100 =

0% - 100%. Available configuration parameters (data type

is 1 Byte DEC):

default value 10

0 - reporting disabled

1 - 100 = 1% - 100% Reporting enabled. Power

report is send (push) only when actual power in

Watts in real time changes for more than set

percentage comparing to previous actual power in

Watts, step is 1%.

NOTE: if power changed is less than 1W, the report is not

send (pushed), independent of percentage set. When

reporting Watts, module will automatically reports also V

(Voltage), A (Amperes), Power factor, kVar (Reactive

Power).

Parameter no. 42 – Power reporting in Watts by time

interval

Set value means time interval (0 – 32535) in seconds,

when power report is send. Available config. parameters

(data type is 2 Byte DEC):

default value 0

0 - Reporting Disabled

1 - 32535 = 1 second - 32535 seconds. Reporting

enabled, Power report is send with time interval set

by entered value. When reporting Watts, module will

automatically reports also V (Voltage), A (Amperes),

Power factor, kVar (Reactive Power).

Parameter no. 45 – Reset Power counters

Available config. parameters (data type is 1 Byte DEC):

default value 0

0 - no function

1 - reset counter 1 – KWh

2 - reset counter 2 – kVARh

4 - reset counter 3 – kVAh

QUBINO SMART METER MANUAL Pdf Download (2024)

References

Top Articles
Latest Posts
Article information

Author: Fredrick Kertzmann

Last Updated:

Views: 6106

Rating: 4.6 / 5 (46 voted)

Reviews: 93% of readers found this page helpful

Author information

Name: Fredrick Kertzmann

Birthday: 2000-04-29

Address: Apt. 203 613 Huels Gateway, Ralphtown, LA 40204

Phone: +2135150832870

Job: Regional Design Producer

Hobby: Nordic skating, Lacemaking, Mountain biking, Rowing, Gardening, Water sports, role-playing games

Introduction: My name is Fredrick Kertzmann, I am a gleaming, encouraging, inexpensive, thankful, tender, quaint, precious person who loves writing and wants to share my knowledge and understanding with you.